Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw

Product Details
Customization: Available
Warranty: 1 Year
Type: Cabinet Air Conditioner
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 23 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (31)
  • Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
  • Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
  • Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
  • Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
  • Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
  • Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Find Similar Products
  • Overview
  • Product Parameters
  • Product Description
  • About Us
  • FAQ
Overview

Basic Info.

Model NO.
BKFR
Weight (Kg)
50 Kg
American Standards
0.75 Ton, 1 Ton, 1.5 Ton, 2.25 Ton, 3.75 Ton
Dimension(L*W*H)
Customized
Types of
Single Cooling, Heating and Cooling
Place of Use
Gas Station, Refinery, Spray Booth, Hazardous
Applicable Industries
Inflammable and Explosive Places
Key Selling Points
Explosion-Proof
Core Components
Other
Metric Standards
2.6 Kw, 3.5 Kw, 5 Kw, 7.26 Kw, 12 Kw
Cable Outer Diameter
10mm-14mm, 15mm-23mm
Trademark
Shen Hai
Origin
Zhejiang, China

Product Description

 
Product Parameters
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Model
 
BKFR-25
BKFR-35
BKFR-50
BKFR-72
BKFR-120
Rated voltage/frequency
 
220V/380V/50Hz
 
 
 
 380V/50Hz
Rated cooling capacity (W)
 
2600
3500
5000
7260
12000
Rated heat (W)
 
2880
3900
5700
8100
12500
Input power (P number)
 
1P
1.5P
2P
3P
5P
Refrigeration input power/current (W/A)
 
742/3.3
1015/4.6
1432/6.5
2200/10
3850/7.5
Heating input power/current (W/A)
 
798/3.6
1190/5.4
1690/7.6
2600/11.8
3800/7.5
Applicable area (m ²)
 
10~12
13~16
22~27
27~34
50~80
Noise (dB)
indoor
34.8/38.8
36.8/40.8
40/45
48
52
 
outdoor
49
50
53
56
60
Overall dimension (mm)
Indoor unit
265x790x170
275x845x180
298x940x200
326x1178x253
581x1780x395
 
Outdoor unit
540x848x320
596x899x378
700x955x396
790x980x440
1032x1250x412
 
Control box
300x500x190
300x500x190
300x500x190
300x500x190
250x380x165
Weight (kg)
Indoor unit
12
10
13
18
63
 
Outdoor unit
11
41
51
68
112
 
Control box
10
 
 
 
7
Length of connecting pipe
 
4
 
 
 
 
Explosion proof sign
 
Ex db eb ib mb IIB T4 Gb,Ex db eb ib mb IIC T4 Gb
 
 
 
 
Maximum outer diameter of incoming cable
 
Φ10~Φ14mm
 
 
Φ15~Φ23mm
 

Split explosion-proof air conditioning treatment

1. Wall mounted explosion-proof air conditioners and floor mounted explosion-proof air conditioners are mainly used for explosion-proof treatment of outdoor units and indoor units on the basis of ordinary air conditioners, as follows: (1) Outdoor unit: it is mainly used for internal electrical control part, compressor, outdoor fan, protection system, heat dissipation system and refrigeration system explosion proof treatment shall be carried out in a unified way. Its overall dimensions are the same as those of the external units of ordinary hanging air conditioners, and its installation method is also the same as that of the external units of ordinary hanging air conditioners. (2) Indoor unit: it mainly adopts special process treatment methods and manufacturing methods to decompose the internal electrical control part, and then re conduct explosion-proof design, manufacturing and processing to form an independent explosion proof control box, with manual control function, its hanging external dimension is the same as that of the ordinary hanging internal machine, and its installation method is also the same. But the explosion-proof indoor unit is increased a hanging explosion-proof control box is provided, and its dimensions are shown in the figure below.
2. A variety of explosion-proof forms are used outside the explosion-proof indoor unit and outdoor unit, and the intrinsically safe explosion-proof circuit is used for the weak current control part.


Security Level: IP66,WF2,Ex db eb ib mb IIB T4 Gb,Ex db eb ib mb IIC T4 Gb
Alias: Explosion Proof Air Conditioner,Ex Proof Air Conditioner
Function: Refrigeration And Heating In Flammable And Explosive Environments

Applicable Scope: Zone 1, Zone 2, Zone 21,Zone 22;IIA, IIB,IIC Explosive Gas Environments
English Standards: 9000 But, 12000 But, 18000 But, 27000 But, 45000 But
Product Description
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
1. Explosion proof air conditioner is made of explosion-proof treatment on the basis of ordinary air conditioner, with reliable explosion-proof performance and no impact on the performance of the original air conditioner.
2. Explosion proof air conditioners can be divided into: split wall mounted type and floor mounted type according to structure, and can be divided into: single cold type and cold and warm type according to function.
3. The connection of explosion-proof air conditioner pipeline is consistent with that of ordinary air conditioner. The electrical connection must be in accordance with the requirements of explosion-proof electrical installation process. The power supply must be introduced into the explosion-proof control box first, and then divided from the explosion-proof control box. Do not introduce the indoor unit and outdoor unit.
4. The explosion-proof control box is equipped with a power switch.
5. Steel pipe or cable wiring is acceptable.
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
1. It is applicable to the places in Zone 1 and Zone 2 of explosive gas environment;
2. Suitable for IIA, IIB and IIC explosive gas environment;
3. Applicable to T1~T6 temperature groups;
4. It is applicable to dangerous environments such as oil exploitation, oil refining, chemical industry, gas station, offshore oil platforms, oil tankers and metal processing;
5. It is used for temperature regulation in workshops, control rooms, laboratories and other fields.
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
About Us
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
 
VR
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
FAQ
Hisense 17100BTU Battery Room Wall Mount Electric Equipment Warehouse Explosion Proof Window Air Conditioner 45kw
A: Are you a manufacturer or a trading company? 
Q: We are a manufacturer and provide OEM services. Our main products are explosion-proof lightings, explosion-proof distribution box, explosion-proof cable gland, explosion-proof fans, explosion-proof junction box and anti-corrosion & dustproof & waterproof lights.  
 
A: What certificates do you have?  
Q: We have passed ATEX, IECEx, and with a lot of National Patents.  
 
A: What filed are your products used in?  
Q: They are widely used in petroleum chemical, aerospace, coal electrical power, railway, metallurgy, shipbuilding, medicine, marine, wine-making, fire fighting, municipal, gas station and other industries.  

A: Can I have a sample order? 
Q: Yes, we welcome sample orders to test and check quality. Mixed samples are acceptable.  
 
A: Will you accept customized?  
Q: Yes. Please inform us and confirm the design firstly based on our sample. 
 
Thanks for your visiting and hope to cooperate!! 
($10 free for the first order)

contact us

Tel: +86 571 8290 1577
 
Company: Shenhai Explosion-Proof Technology Co., Ltd.
Address:
RM.1204, Lanjue International Centre, No.358 Jincheng Rd., Xiaoshan Dist., Hangzhou CY, Zhejiang Prov., P.R.C. (P.O.: 311202)
No. 318, Wei15 Road,Yueqing Economic Development Zone, Wenzhou, Zhejiang, China.
Click to return to the home page

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier